Technical Parameters:
Medium: Liquid, Gas, Steam
Nominal Diameter: DN15~DN300(wafer/flange type); DN200~DN2500(insertion type)
Medium Temperature: -50~+500℃
Nominal Pressure: 1.6Mpa, 2.5Mpa, 4.0Mpa, Higher pressure can be customized.
Accuracy: Liquid: ±1.0% reading; Gas, Steam: ±1.5% reading
Repeatability: ≤1/3 accuracy
Power Supply: 24VDC
Output Signal: Pulse output/ 4-20mA.DC/ RS485
Ex-proof: Flame proof: ExdIIBT5; Intrinsic safety: ExiaIICT5
Protection level: IP65, IP68